Performance of an irradiated LHCb prototype p-on-n silicon microstrip detector

Bowcock, T. and Buytaert, J. and Casse, G. and Charles, M. and Dijkstra, H. and Collins, P. and Dormond, O. and Ferro-Luzzi, M. and Fiedler, F. and Frei, Regina and Gagliardi, G. and Jalocha, P. and Libby, J. and Ketel, T. and Parkes, C. and Parzefall, U. and Ruf, T. and Tareb, M. and Teubert, F. and Wright, V. and Witek, M. (2002) Performance of an irradiated LHCb prototype p-on-n silicon microstrip detector. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 478 (1-2). 291 - 295. ISSN 0168-9002

Type of Research: Article
Creators: Bowcock, T. and Buytaert, J. and Casse, G. and Charles, M. and Dijkstra, H. and Collins, P. and Dormond, O. and Ferro-Luzzi, M. and Fiedler, F. and Frei, Regina and Gagliardi, G. and Jalocha, P. and Libby, J. and Ketel, T. and Parkes, C. and Parzefall, U. and Ruf, T. and Tareb, M. and Teubert, F. and Wright, V. and Witek, M.
Description:

A prototype silicon detector for the LHCb experiment has been irradiated non-uniformly with fluences of up to 10 15 p/cm2 of 24 GeV protons and tested with LHC speed electronics in a test beam. After doses equivalent to one year of operation at the LHC, the detector was operational, and deteriorated after higher doses. The performance of this detector identifies particular risks associated with a p-on-n fine pitch design with a double metal layer.

Publisher/Broadcaster/Company: Elsevier
Your affiliations with UAL: Colleges > London College of Fashion
Date: 1 February 2002
Digital Object Identifier: 10.1016/S0168-9002(01)01812-5
Date Deposited: 02 Aug 2024 13:44
Last Modified: 14 Aug 2024 14:27
Item ID: 22349
URI: https://ualresearchonline.arts.ac.uk/id/eprint/22349

Repository Staff Only: item control page | University Staff: Request a correction